Brand Name : Comking

Model Number : CKVB-24/GE

Certification : Type Test Report

Place of Origin : China

Payment Terms : L/C, T/T, Western Union

Packaging Details : Wooden Packing

MOQ : 1set

Price : To be discussed later

Delivery Time : 10-15 work days

Rated voltage : 24kV

Rated current : 630A,1250A

Rated frequency : 50Hz

Type : Indoor

Contact Now

1. CKVB-24/GE is the circuit breaker with right lateral.

2. Technical Data

Description Unit Parameter
Rated voltage kA 24
Rated short-time withstand voltage phase-to-phase phase-to-earth kA 65
open contact kA 79
Rated lighting impulse withstand voltage phase-to-phase phase-to-earth kA 125
open contact kA 145
Rated frequency Hz 50
Pole centre distance mm 210, 230
Rated current A 630 1250
Rated short-time withstand current(4s) kA 25 31.5 25 31.5
Rated peak withstand current kA 63 80 63 80
Rated short-circuit breaking current kA 25 31.5 25 31.5
Rated short-circuit making current kA 63 80 63 80
Rated breaking cable charging current A 25
Rated capacitor bank inrush making current kA 12.5
Rated single capacitor bank breaking current A 630
Rated back to back capacitor bank breaking current A 400
Operating sequence / Opening-0.3s-Closing/Opening-180s-Closing/Opening
Mechanism life times 20000
Opening times for rated current times 20000
Opening times for rated short-circuit current times 50
Clearance between open contacts mm 13±1
Overtravel mm 4±1
Average closing speed m/s 0.8~1.2
Average opening speed m/s 1.1~1.7
Closing time ms 35~70
Opening time ms 20~50
Bounce time for contact’s closing ms ≤2
Asynchronous time for three-phase contacts closing / opening ms ≤1
Allowable accumulated wearing thickness of moving/fixing contact mm 3

3. Standard

----GB1984-2003

---- IEC60056-2001

---- GB/T16927-1997

---- GB/T 4473-2008

---- DL/T403-2000

--- J B/T3855-2008

4. Working Condition

4.1 Ambient air temperature: -25℃~+40℃

4.2 Ambient humidity:

---- relative average daily humidity: ≤95%

---- relative average daily water vapor pressure: ≤2.2kPa

---- relative average monthly humidity: ≤90%

---- relative average monthly water vapor pressure: ≤1.8kPa

4.3 Altitude: ≤1000m

4.4 Earthquake intensity: ≤magnitude 8

4.5 Ambient air doesn’t obviously pollute by dust, smoke, corrosive or combustible gas, vapors or salt spray.

(Exceeding above working condition is available as customized product)


Product Tags:

vcb circuit breaker

      

electrical circuit breaker

      
China Front Panel Installation Indoor Vacuum Circuit Breaker Environmental Friendly wholesale

Front Panel Installation Indoor Vacuum Circuit Breaker Environmental Friendly Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Zhuhai Comking Electric Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)